null
Skip to main content

Cisco

NEW Cisco A9K-MOD80-SE 2x Open Expansion Module Slot (Service Edge) Line Card

UPC: 882658702662
Condition: New
Shipping: Calculated at Checkout
Warranty: 365 days
CALL: 877-263-8436
E-MAIL: sales@networkgenetics.net
$1,799.00

A9K-MOD80-SE-new OverviewA9K-MOD80-SE is Cisco ASR 9000 Mod80 Modular Line Card, Service Edge Optimized, requires modular port adapters. Cisco ASR 9000 Series mo…

Adding to cart… The item has been added

A9K-MOD80-SE-new Overview

A9K-MOD80-SE is Cisco ASR 9000 Mod80 Modular Line Card, Service Edge Optimized, requires modular port adapters. Cisco ASR 9000 Series modular line cards provide customers with a flexible solution supporting multiple combinations of Ethernet ports, all in a single slot of the Cisco ASR 9000 Series Aggregation Services Routers. Modular line cards support a wide range of interfaces and densities.

Quick spec of A9K-MOD80-SE-new

  • Product Number : A9K-MOD80-SE
  • Type : ASR 9000 Mod80 Modular Line Card, Service Edge Optimized, requires modular port adapters
  • Physical Dimensions : 14.5 W x 1.72 H x 22.40 L 14.5 W x 1.72 H x 24.25 L (including ejector levers)
  • Weight : 17.5 lbs. (est.) (7.93 Kg)
  • Chassis compatibility : Compatible with the Cisco ASR 9922, 9010, 9006 and 9001 systems
  • Port density : Up to 2 modular port adapters are supported per line card.

A9K-MOD80-SE-new Specification

  • Type :ASR 9000 Mod80 Modular Line Card, Service Edge Optimized, requires modular port adapters
  • Physical Dimensions :14.5 W x 1.72 H x 22.40 L 14.5 W x 1.72 H x 24.25 L (including ejector levers)
  • Weight :17.5 lbs. (est.) (7.93 Kg)
  • Chassis compatibility :Compatible with the Cisco ASR 9922, 9010, 9006 and 9001 systems
  • Port density :Up to 2 modular port adapters are supported per line card.
  • Ethernet :· IEEE 802.3 compliant · 10 Gigabit Ethernet PHY monitoring · IEEE 802.x flow control · Full-duplex operation · Per-port byte and packet counters for policy drops; oversubscription drops; cyclic redundancy check (CRC) error drops; packet sizes; and unicast, multicast, and broadcast packets
  • Card density :Maximum number of line cards per system: Cisco ASR 9922 = 20, Cisco ASR 9010 = 8, and Cisco ASR 9006 = 4
  • Options :Each line card is available as either a Service Edge Optimized (enhanced QoS) or Packet Transport Optimized (basic QoS) line card.
  • Reliability and availability :Line card online insertion and removal (OIR) support without system impact
  • Network Equipment Building Standards (NEBS) :Cisco ASR 9000 Series Routers are designed to meet: · SR-3580: NEBS Criteria Levels (Level 3) · GR-1089-CORE: NEBS EMC and Safety · GR-63-CORE: NEBS Physical Protection
  • Operating temperature (nominal) :41 to 104ºF (5 to 40ºC)
  • Operating temperature (short-term) :23 to 131ºF (–5 to 55ºC)
  • Operating humidity (nominal) relative humidity :10 to 85%
  • Storage temperature :–40 to 158ºF (–40 to 70ºC)
  • Storage relative humidity :5 to 95% Note: Not to exceed 0.024 kg of water per kg of dry air
  • Operating altitude :–60 to 4000m (up to 2000m conforms to IEC, EN, UL, and CSA 60950 requirements)
  • ETSI standards :Cisco ASR 9000 Series Routers are designed to meet: · EN300 386: Telecommunications Network Equipment (EMC) · ETSI 300 019 Storage Class 1.1 · ETSI 300 019 Transportation Class 2.3 · ETSI 300 019 Stationary Use Class 3.1 · EN55022: Information Technology Equipment (Emissions) · EN55024: Information Technology Equipment (Immunity) · EN50082-1/EN-61000-6-1: Generic Immunity Standard
  • EMC standards :Cisco ASR 9000 Series Routers are designed to meet: · FCC Class A · ICES 003 Class A · AS/NZS 3548 Class A · CISPR 22 (EN55022) Class A · VCCI Class A · BSMI Class A · IEC/EN 61000-3-2: Power Line Harmonics · IEC/EN 61000-3-3: Voltage Fluctuations and Flicker
  • Immunity :Cisco ASR 9000 Series Routers are designed to meet: · IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8kV Contact, 15kV Air) · IEC/EN-61000-4-3: Radiated Immunity (10V/m) · IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2kV Power, 1kV Signal) · IEC/EN-61000-4-5: Surge AC Port (4kV CM, 2kV DM) · IEC/EN-61000-4-5: Signal Ports (1kV) · IEC/EN-61000-4-5: Surge DC Port (1kV) · IEC/EN-61000-4-6: Immunity to Conducted Disturbances (10Vrms) · IEC/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30A/m) · IEC/EN-61000-4-11: Voltage DIPS, Short Interruptions, and Voltage Variations
  • Safety :Cisco ASR 9000 Series Routers are designed to meet: · UL/CSA/IEC/EN 60950-1 · IEC/EN 60825 Laser Safety · ACA TS001 · AS/NZS 60950 · FDA: Code of Federal Regulations Laser Safety

Customer Reviews

This product hasn't received any reviews yet. Be the first to review this product!

Recent Viewed Products

Review Your Cart Close Close
Your cart is empty Your cart is empty Your cart is empty
Recently Viewed Recently Viewed
Social Media Social Media
Back to top Back to top